• Zhengzhou,Henan,China
  • alummc@hotmail.com

80" Aluminum Laser Tracker Scale Bars - ATT-Metrology

80″ Aluminum Laser Tracker Scale Bars. $1,075.00 – $1,860.00. Function. Used to set or check scale on aluminum parts. Available for use with either 1.5″ or 0.5″ SMRs. Features. Distance between the targets is built to 80.00″. +/-.030″ with the actual distance measured and certified to +/-.0005. The bar is made with high visibility ...

80" Steel Laser Tracker Scale Bars - ATT-Metrology

80″ Steel Laser Tracker Scale Bars. $1,075.00 – $1,715.00. Function. Used to set or check scale on Steel parts. Available for use with either 1.5″ or 0.5″ SMRs. Features. Distance between the targets is built to 80.00″ +/-.030″ with the actual distance measured and certified to +/-.0005. High visibility yellow powder coat with ...

Scale Bars - ATT-Metrology

Scale Bars - ATT-Metrology. View All Targets Go Back. 48" Aluminum, Steel Carbon Fiber Photogrammetry Scale Bars. BUY HERE. 80" Aluminum Laser Tracker Scale Bars. BUY HERE.

80" Carbon Fiber Laser Tracker Scale Bars - ATT-Metrology

80″ Carbon Fiber Laser Tracker Scale Bars. $1,075.00 – $3,874.00. Function. The ATT Metrology Services Carbon Fiber Laser Tracker Scale Bar is designed from High Strength, Low Weight, Dimensionally stable Carbon Fiber Material with a near zero Coefficient of Thermal Expansion (CTE). The advantage of this Scale bar design and material is ...

Scale Bars for Laser Trackers - Brunson

Our scale bars are made of Invar material to provide a thermally stable reference length for use during laser tracker or scanner jobs. Use them to establish or verify system scale. Some customers shoot our scale bars before, during,and after a job to gain confidence that the instrument has not shifted during the "shoot". Our Low Thermal Expansion scale bar employs a simple mechanism to reduce ...

Metrology Scale Bars for Laser Trackers - Brunson

Use our scale bars with your laser tracker (or laser radar) to verify system accuracy and stability during a measurement job. Many of our customers shoot a length reference bar at the beginning, middle, and end of a job to gain confidence that nothing moved or changed during the job. View as

A Laser Tracker Calibration System - NIST

constraints, re-calibration of the scale bar during the extensive performance tests is not typically performed. As a result, any drift in the artifact dimensions due to a change in its temperature may mask or exaggerate tracker measurement errors. For artifact materials such as steel and aluminum, the thermal drift due to temperature

80" Aluminum Laser Tracker Scale Bars - ATT-Metrology

80″ Aluminum Laser Tracker Scale Bars. $1,075.00 – $1,860.00. Function. Used to set or check scale on aluminum parts. Available for use with either 1.5″ or 0.5″ SMRs. Features. Distance between the targets is built to 80.00″. +/-.030″ with the actual distance measured and certified to +/-.0005. The bar is made with high visibility ...

Scale Bars - ATT-Metrology

Scale Bars - ATT-Metrology. View All Targets Go Back. 48" Aluminum, Steel Carbon Fiber Photogrammetry Scale Bars. BUY HERE. 80" Aluminum Laser Tracker Scale Bars. BUY HERE.

Scale Bars for Laser Trackers - Brunson

Our scale bars are made of Invar material to provide a thermally stable reference length for use during laser tracker or scanner jobs. Use them to establish or verify system scale. Some customers shoot our scale bars before, during,and after a job to gain confidence that the instrument has not shifted during the "shoot". Our Low Thermal Expansion scale bar employs a simple mechanism to reduce ...

Metrology Scale Bars for Laser Trackers - Brunson

Use our scale bars with your laser tracker (or laser radar) to verify system accuracy and stability during a measurement job. Many of our customers shoot a length reference bar at the beginning, middle, and end of a job to gain confidence that nothing moved or changed during the job. View as

A Laser Tracker Calibration System - NIST

constraints, re-calibration of the scale bar during the extensive performance tests is not typically performed. As a result, any drift in the artifact dimensions due to a change in its temperature may mask or exaggerate tracker measurement errors. For artifact materials such as steel and aluminum, the thermal drift due to temperature

Tech Tip - Compensating for Thermal Expansion - 3D ...

Mar 09, 2018  Above: Laser Tracker Scale Bar with Three Certified Distances. CTE after Measurements When Points and Features have been measured using the Standard 68˚F or 20˚C Material Temperature but the object temperature varies it is possible to correct the measured Points and Features for temperature after the measurement process has been completed.

Laser Tracker Tooling Accessories – MetrologyWorks

Laser Tracker Tooling Accessories. MetrologyWorks provides a full line of Laser Tracker Accessories as well as Laser Tracker Tooling and Adapters. This includes Drift Nests, Permanent Monuments, Pin Nests, Edge Nests, Hidden Point Bars. If you need something custom we can provide custom Laser Tracker Tooling as well.

Methods to calibrate a three-sphere scale bar for laser ...

Feb 01, 2020  Feb 01, 2020  This method involves placing the laser tracker centrally behind the scale bar, at the same height as the scale bar, and at a distance that allows the laser beam to enter each SMR without obstruction (see Fig. 3).With the laser tracker in this orientation, each SMR is measured in both front- and back-face.

Scale-bar artifact and methods of use - Faro Laser ...

Although a calibrated scale-bar is often required for the testing of coordinate measurement devices, including the three degree-of-freedom laser tracker and the one degree-of-freedom ADM, there are practical problems in obtaining calibrated scale-bars that are sufficiently accurate over the wide range of temperatures that are present in many ...

bal-tec - All Ball Bar Information

A complete 900 mm stand alone Laser Tracker Calibration System Our Part #CBBR-900- (specify the SMR diameter, .5 or .875 or 1.5 ) includes a 900 mm (35.4 inches ) long “Centerline Ball Bar Ranger,” a Wayout Ball Bar Support, a 14inch (356 mm ) a Heavy Duty Trivet, a 36 inch (941 mm ) tall 3 inch (76 mm ) diameter Anchor, and a Tri-Mount Collar.

Helping Laser Scanners Measure Up NIST

Apr 23, 2020  Apr 23, 2020  The new method eliminates the need to drill holes in the targets and enables precision measurements with the laser tracker set up a couple of meters from the scale bar. Because the targets are rigidly attached to the scale bar, and the bar is inflexible, the main source of uncertainty in measuring scale-bar dimensions is the “ranging ...

MetrologyStore

Aluminum Common Point for 1,5'' SMRs. Al - 1,5 - CP- PLANEAluminum Common Point for 1,5'' SMRsAluminum common points target for 1,5'.. €9.00. ... Flight case for 2 m Scale Bar. Flight case for Scale BarA flight case is a transportation container used

Brunson Instrument Company - ACQUIP Laser Alignment

Laser Tracker Products. Target Holders. For 1.5" Reflectors; For 0.875" Reflectors; For 0.5" Reflectors; Target Holder Kits; Targeting Accessories; Scale Bars; Scale Bar Kits; KinAiry Laser Tracker Field Test. Bar Artifact; Stands; Software; Scanning Instrument Positioner; Metrology Stands Accessories. Heavy Duty Metrology Stands; Portable ...

ZOENHOU 100 PCS 3.4 x 2.1 Inch Thickness 8mil Metal ...

Nov 17, 2021  Nov 17, 2021  ZOENHOU 100 PCS 3.4 x 2.1 Inch Thickness 8mil Metal Business Card, Silver Blanks Finished Aluminum Blank Name Cards Metallic DIY Gift Cards VIP Cards

Laser Tracker Tooling Accessories – MetrologyWorks

Laser Tracker Tooling Accessories. MetrologyWorks provides a full line of Laser Tracker Accessories as well as Laser Tracker Tooling and Adapters. This includes Drift Nests, Permanent Monuments, Pin Nests, Edge Nests, Hidden Point Bars. If you need something custom we can provide custom Laser Tracker Tooling as well.

US20020148133A1 - Scale-bar artifact and methods of use ...

A scale-bar artifact is and measurement method is provided, the artifact comprising a shaft, at least one mounting nest positioned on the shaft, a plurality of target nests positioned on the shaft, at least one temperature sensor in contact with the material of the shaft and a computer or circuit board in communication with the at least one temperature sensor, wherein the computer or circuit ...

Methods to calibrate a three-sphere scale bar for laser ...

Feb 01, 2020  This method involves placing the laser tracker centrally behind the scale bar, at the same height as the scale bar, and at a distance that allows the laser beam to enter each SMR without obstruction (see Fig. 3).With the laser tracker in this orientation, each SMR is measured in both front-

Photogrammetric Deflection Measurements for the Tiltrotor ...

1990's to test small-and large-scale rotor systems as described in Refs. 1-3. Based upon the RTA experience (Ref. 1), the LRTA included the design of a calibration stand, which enabled an LRTA-installed rotor balance calibration. Deflection measurements using a laser tracker were acquired during the LRTA balance calibration.

Temperature Compensation for Portable Metrology Hexagon

1. Reference scale bars made of the same material as the part to be measured (this technique is a hold-over from theodolite measurement systems). 2. Another similar technique is to measure two points on the tool and tell the measurement system the “known” distance between those two points. This is a variation of the scale bar method. 3.

Integration Spheres • ScanningSpheres

These spheres are aluminum with a “satin finish“, which means they have an ideal lambertian finish for laser scanning. The ball is hollowed out and a nest is created inside to locate a 1.5 inch (38mm) diameter SMR. The location of the integration sphere can be measured

Compensating for Thermal Expansion – Got Metrology?

This values are general in nature and vary depending on the exact type of Aluminum being used. ... If the system being utilized requires the use of a Certified Scale Bar to determine Scale the equipment can provide accurate “Scale” ONLY when the Scale Bar Material and Temperature are the SAME as the part ... Checking Laser Tracker Accuracy.

(PDF) Improvised Long Test Lengths via Stitching Scale Bar ...

May 28, 2020  (2) Scale bar bending effects : Our current sc ale bar prototype is a modification of the short scale bar proposed by Lee and Saw yer [16] , which was

Compensating for Thermal Expansion – does size matter ...

Jan 30, 2012  These Ball Bars typically have a calibrated distance between the two spheres. Scale Bars typically have magnetic mounts at each end to accept Laser Tracker Spherically Mounted Reflectors (SMR's) or highly accurate Sphere's. The distance between the points is calibrated by using highly accurate Laser Interferometers. Certified Scale Bars

Calibration Repair - Brunson

Repair and Calibration for Optical Tooling and more Use our Online Calibration Repair request form (to return an instrument for calibration or repair) Brunson Instrument offers calibration services for optical measurement and alignment equipment, including optical tooling (all types and brands), theodolites, automatic levels, and more.

Our Equipment - e3D Technology Corp

The Vantage S laser tracker's accuracy and real-time feedback capability makes it ideal for tool building, complex layouts/alignments, and dimensional problem-solving. The Vantage S's ability to measure at ranges of up to 80 metres (262.5 feet) makes it especially suitable for large-scale applications.

Brunson Instrument Company - ACQUIP Laser Alignment

Laser Tracker Products. Target Holders. For 1.5" Reflectors; For 0.875" Reflectors; For 0.5" Reflectors; Target Holder Kits; Targeting Accessories; Scale Bars; Scale Bar Kits; KinAiry Laser Tracker Field Test. Bar Artifact; Stands; Software; Scanning Instrument Positioner; Metrology Stands Accessories. Heavy Duty Metrology Stands; Portable ...

The Ones Stop Survey Shop

The 12” bar holds a 1.5” SMR in the center of a virtual 24” sphere. The precision radius probe provides the user an easy to use and robust hidden point probe. Simply change the SMR diameter to 24” in the measurement software and measure behind ribs, steps and other geometry that blocks the line of site to the point that needs to be checked.

Hexagon Manufacturing Intelligence

Hexagon Manufacturing Intelligence exists to help customers rapidly transform their manufacturing business by enabling them to work at the speed they need to, while inspiring complete confidence in the reliability of their processes and the quality of their output.

blue laser line scanner iScan to scan all surfaces - API ...

∓ 80 μm: ∓ 20 μm + ∓ 4 μm/m ... SLU and RU are further specified as a function of the distance between the laser tracker and the measured surface. *These values represent the Maximum Permissible Error(MPE) between a verified Scale Bar and the expected performance of the instrument. *Nominal Values are established by the Laser Tracker.

Brunson Instrument Company - ACQUIP Laser Alignment

Laser Tracker Products. Target Holders. For 1.5" Reflectors; For 0.875" Reflectors; For 0.5" Reflectors; Target Holder Kits; Targeting Accessories; Scale Bars; Scale Bar Kits; KinAiry Laser Tracker Field Test. Bar Artifact; Stands; Software; Scanning Instrument Positioner; Metrology Stands Accessories. Heavy Duty Metrology Stands; Portable ...

bal-tec - All Ball Bar Information

A complete 900 mm stand alone Laser Tracker Calibration System Our Part #CBBR-900- (specify the SMR diameter, .5 or .875 or 1.5 ) includes a 900 mm (35.4 inches ) long “Centerline Ball Bar Ranger,” a Wayout Ball Bar Support, a 14inch (356 mm ) a Heavy Duty Trivet, a 36 inch (941 mm ) tall 3 inch (76 mm ) diameter Anchor, and a Tri-Mount Collar.

Tripods - AXIST SRL

186 CM-Heavy Duty Adjustable Height Tripod. Heavy Duty Adjustable Height Tripod - 186 CMThese aluminum tripods are widely applicable and ar..

US8141264B2 - Length reference bar system and method ...

A length reference bar system and method that compensates for thermal expansion and allows for testing whether an instrument is working properly using only an inferometer. The length reference bar system has a bar portion with end caps for target positions on either end of the bar portion that extend inward toward each other such that, if a length of the bar portion changes due to a ...

EP1719580B1 - Laser projection system - Google Patents

EP1719580B1 EP06112293A EP06112293A EP1719580B1 EP 1719580 B1 EP1719580 B1 EP 1719580B1 EP 06112293 A EP06112293 A EP 06112293A EP 06112293 A EP06112293 A EP 06112293A EP 1719580 B1 EP1719580 B1 EP 1719580B1 Authority EP European Patent Office Prior art keywords laser metrology projector laser projector frame Prior art date 2003-09-10 Legal status (The

Measurement Talk – Got Metrology?

The arrival of the Laser Tracker with improved accuracy and the ability to measure 1000 points per second, also brought about big changes in tooling tolerances, suddenly, the +/- 0.010 inch tolerances of the past, were no longer acceptable, with many Engineers expecting that tooling could be built to the tolerance of the Laser Tracker (=/- 0 ...

Testing Proposal for An Optically Tracked CMM in a Pre ...

May 17, 2017  The scale bars were probed with a 0.5 in. hemispherical anodized-aluminum ball stylus for both CMS. The results indicate again negatives errors for the OTCMM (see table 7). We could not see any trend due to distance between length artifact and optical tracking unit and its orientation.

The Ones Stop Survey Shop

The 12” bar holds a 1.5” SMR in the center of a virtual 24” sphere. The precision radius probe provides the user an easy to use and robust hidden point probe. Simply change the SMR diameter to 24” in the measurement software and measure behind ribs, steps and other geometry that blocks the line of site to the point that needs to be checked.

Large-Scale Metrology – An Update - ScienceDirect

Jan 01, 2002  Abstract. Developments in large-scale engineering metrology since the 1978 report of Puttock are reviewed. Advances in optical technology and fast, low-cost computation have led to wide-spread use of laser trackers and digital photogrammetry for general-purpose coordinate metrology. Techniques for high-accuracy straightness measurement ...

Torpedo Levels Lasers for sale eBay

DEWALT N096400 Roll Cage. 4.6 out of 5 stars. (9) Total Ratings 9, $41.99 New. Lenox Magnetic Torpedo Level 9 Inch 4 Vials Billet Aluminum CHN LXHT82658. $13.99 New. Go to next slide -

Miscellaneous - Hubbs Machine

CB . Intended to be used when standard, off the shelf designs, such as .3125 and .5000 offsets with .2500 shanks, cannot be used. All of are balls are welded to

Temperature Compensation Quality Digest

May 10, 2011  Imagine a piece of aluminum that measures 48 in. in a 68°F controlled inspection lab. The laser tracker will measure the bar at 48 in., but placing it in an environment that is 90°F would cause the bar to experience a thermal linear growth of approximately 0.013 in.

Orientation Uncertainty Characteristics of Some Pose ...

Two vector bars were used in the experiment, and each vector bar contains two detectors which define a vector in space (the detectors in a vector bar were separated by 101.6 mm). The two vector bars rigidly mounted to an aluminum rail were used to create a local coordinate frame: in commercial applications, a rigid object remains fixed in the ...

Send A Message